Skip to main content
QuickServer Gateway

QuickServer Gateway

Offer functionality for configuration, monitoring, logging, security diagnostics, and updates

The QuickServer is a family of high-performance, fully configurable, and cost-effective building and industrial automation IIoT gateways for integrators to easily connect to the cloud and interface devices to networks in commercial buildings, campuses, and industrial facilities. The QuickServer supports up to 250 data points and can connect to serial, Ethernet, and/or LonWorks Free Topology (FT) links. For up to 500 data points and optional RS-232 and RS-422 serial outputs, see the Enhanced version.

This product is protected by FieldSafe.
Show Less
Read More
QuickServer Gateway
QuickServer Gateway
Offer functionality for configuration, monitoring, logging, security diagnostics, and updates
Highlights
Videos
Options
Approvals
Literature
Highlights

Enjoy the benefits of the cloud connectivity through the MSA Grid. The QuickServer Enhanced is MSA Grid-enabled, meaning all QuickServers can be registered to the MSA Grid, MSA’s device cloud for the IIoT. The MSA Grid web interface lets users remotely access, in a secure fashion, the FS-GUI application that is available locally on the QuickServer. These applications offer functionality for configuration, monitoring, logging, security, diagnostics, and updates.

1. MSA GRID SUPPORT
Register your QuickServer to the MSA Grid interface for remote access to local applications, configuration, and device management

2. 140+ PROTOCOLS
Allows integrator to complete any project with any protocol on-time

3. BTL, LONMARK CERTIFICATIONS
Full compliance with standards allows integrator to complete projects quickly without downstream interoperability issues

4. 250 POINTS
Sized for most common integration projects

5. CONFIGURATION PROFILES
Quickly and easily configure the product

6. FIELDSERVER TOOLBOX
Perform quick diagnostics, troubleshooting, easy IP details set-up, and status updates

7. ADVANCED AUTO-DISCOVERY
Automatically discover known devices on the network and be configured to provide the protocol translation necessary

  • Easily support one or multiple of the same or different devices without having to build any specific configuration files
  • Automatically build the configuration file of known devices and download the file
  • 8. CONFIGURATION AUTO-SELECTOR
    Enable manufacturers to pre-load multiple predefined configurations

  • Store multiple predefined configuration files
  • Select the active configuration file with DIP switches on the fly
  • Download different configuration file using the FS-GUI (Graphical User Interface)
  • Include up to 250 Modbus registers in a configuration file
  • Videos
    Show More Videos
    Show Less Videos
    Options
    Environment Operating temperature: -40oC to 75oC (-40oF to 167oF)
    Relative humidity: 5-90% RH non-condensing
    Communication Serial RS-485:
  • Galvanic Isolation
  • Baud: 4800, 9600, 19200, 38400, 57600, 115200
  • Ethernet:
  • 10/100 BaseT
  • MDIX
  • DHCP
  • Power Requirements Classic QuickServer:
    9-30VDC or 12-24VAC
  • (RS-422 = 15-30VDC or 12-24VAC)
  • Current draw @ 12V:
  • FS-QS-1010: 240 mA
  • FS-QS-1011: 250 mA
  • M-Bus:
  • Slave: 550 mA@ 12V
  • Master (1 Slave): 580 mA @ 12V
  • Master (64 Slave): 980 mA @ 12V
  • QuickServer:
    9-30VDC or 24VAC
    Enclosure Classic QuickServer:
    Dimensions: 5.05 x 2.91 x 1.6 in. (12.82 x 7.39 x 4.06 cm)
    Weight: 0.4 lbs (0.2 kg)

    QuickServer:
    Dimensions: 4 x 1.1 x 2.7 in (10.16 x 2.8 x 6.8cm)
    Weight: 0.4 lbs (0.2 Kg)
    LonMark Certification on the
    QuickServer FS-QS-1XX1-XXX
    SPID: 80:00:95:46:00:84:04:01

    Profiles:
  • 0000 – Node object (1)
  • 0001 – Open Loop Sensor Object (5)
  • 0003 – Open Loop Actuator Object
  • Other Classic QuickServer:
    Configuration/Diagnostic utilities
    Capacity: 250 -5,000 points
    Table, wall, or DIN rail mount

    QuickServer:
    Configuration/Diagnostic utilities
    Capacity: 250 -5,000 points
    DIN rail mount
    Approvals
    Approvals subject to change without notice and may differ based on configuration, part number and/or country. Contact Customer Service or check approval label on product for specific approval information.
    Literature
    Part Number(s)

    Ask a Question


    Thank you! An MSA representative will be in touch soon.