Skip to main content
BACnet Router

BACnet Router

A Versatile Interoperability Solution

MSA FieldServer offers a complete BACnet internetworking solution for BACnet/IP, BACnet Ethernet, and BACnet MS/TP networks, while also providing a secure connection to the cloud. Multiple BACnet routing connections can be established:

  • BACnet MS/TP to BACnet/IP
  • BACnet MS/TP to BACnet Ethernet
  • BACnet MS/TP to BACnet MS/TP
  • BACnet/IP to BACnet/IP
  • BACnet/IP to BACnet Ethernet

The FieldServer BACnet Router has dual BACnet MS/TP ports with a Wi-Fi option for a BACnet/IP connection.

This product is protected by FieldSafe.

 

 

Show Less
Read More
BACnet Router
BACnet Router
A Versatile Interoperability Solution
Highlights
Videos
Options
Approvals
Literature
Highlights
Innovative Features

The dual-port BACnet Router has two RS-485 ports, enabling connection to up to 64 BACnet devices without the use of additional line drivers. Using a BACnet router frees up valuable RS-485 ports on expensive BACnet Controllers and reduces the cost of connecting BACnet MS/TP devices to a BACnet/IP backbone. Compared to single-port BACnet routers, our dual-port BACnet router can reduce the cost of device connectivity or double the speed of connected devices (half the response time).

BACnet Explorer, our unique discovery feature, allows the integrator to discover all the BACnet devices connected to the router with one push of a button, minimizing the time required for successful commissioning. Complementing this feature is our diagnostic FieldServer Toolbox, which allows the user or integrator to view the status of and diagnose all the routers on the network.

1. MSA GRID SUPPORT
  • Register your BACnet Router to the MSA Grid interface for remote access to local applications, configuration, and device management
2. BACNET EXPLORER
  • Minimize commissioning time by automatically discovering all BACnet devices connected to a BACnet network.
3. BTL CERTIFICATION
  • Most compliant and highest quality BACnet stack enables interoperability and reduces troubleshooting time
4. DUAL RS-485 PORT OPTION
  • Results in lowest cost per connected device or highest performance (response time) per connected device
5. EASY CONFIGURATION WITH DISCOVERY
  • One page set and forget configuration along with unique network discover capability minimizes the integrator's installation time. 
Videos
Show More Videos
Show Less Videos
Options

Model Numbers

  • FS-ROUTER-BAC2: 2 Serial Ports

Communication

  • Serial RS-485
    • Galvanic isolation
    • Baud: 9600, 19200, 38400, 57600, 76800, 115200
  • Ethernet
    • 10/100 BaseT
    • MDIX
    • DHCP

Environment

  • Operating Temperature: -40o to 167oF (-40o to 75oC)
  • Relative Humidity: 5-90% RH non-condensing

Power Requirements

  • 9-30 VDC or 24 VAC
  • Current draw @ 12V: 240 mA

Physical Dimensions

  • 4.5 x 2.9 x 1.7 in. (10.16 x 2.8 x 6.8 cm)
  • 0.4 lb (0.2 Kg)

Other

  • Web Configuration
  • Toolbox diagnostic utility
  • DIN rail mount included

 

Approvals
Approvals subject to change without notice and may differ based on configuration, part number and/or country. Contact Customer Service or check approval label on product for specific approval information.
Literature
Part Number(s)

Ask a Question