火焰和气体监测系统

Zero Two 系列火灾和气体检测系统

Zero Two 系列火灾和气体检测系统

此模块系统提供广泛的控制卡系列,以供在集成式火灾和/或气体检测系统中使用。Zero Two 系列系统可监测以下各项的任意组合:可燃气体、硫化氢、有毒气体、超声波、氧气不足和火焰检测。此外,其开放式架构使得系统可以容纳其他传感器设备,以用于各种任务,如烟雾检测、热检测和手动报警点。
TA102A Single Channel Combustible Trip Amplifier Module

TA102A Single Channel Combustible Trip Amplifier Module

The TA102A is a single-channel Combustible Gas Trip Amplifier Module designed for use with one General Monitors intelligent transmitter to monitor combustible gases and vapors within the lower explosive limit (LEL) and provide status indication and alarm outputs. Microprocessor-based electronics allow all options to be user selectable through a front panel interface (mode / select switch and digital display). A digital display indicates fault codes and set up options. Other features include: LED indications of status, as well as both open collector and relay outputs for fault, low alarm and high alarm.
4802A Zero Two 系列控制模块,用于可燃气体应用场合

4802A Zero Two 系列控制模块,用于可燃气体应用场合

4802A 是一个单通道可燃气体控制模块,专为与我们的经过验证的催化珠传感器一同使用而设计。它用于监测具有低爆炸下限 (LEL) 浓度的可燃气体和蒸气,并提供状态指示和报警输出。基于微处理器的电子装置允许用户通过前面板界面来选择所有选项。数字显示屏指示气体浓度、故障码、标定提示和设置选项。其他功能:状态的 LED 指示,以及集电极开路和继电器输出。
CC02A Serial Communications Module

CC02A Serial Communications Module

The CC02A Communications Card facilitates serial communications between each module in a Zero Two Series Flame and Gas Detection System and an external host computer, which allows fast access to operational and setup data registers. It supports a Burst Read feature that returns all registers of a module in a single transmission.
DT210 Eight Channel H2S Readout / Relay Module

DT210 Eight Channel H2S Readout / Relay Module

The DT210 is an eight-channel Readout / Relay Module designed for use with up to eight of our remotely located H2S Intelligent Sensors. The front panel contains a digital display that indicates 0-20 ppm (parts per million), 0-50 ppm, or 0-99 ppm of the hydrogen sulfide gas monitored by the Intelligent Sensors.
FM002A Facilities Module

FM002A Facilities Module

The FM002A is a facilities module that provides a range of common facilities for all Zero Two control modules housed in the chassis. The FM002A is plugged into the last slot on the right-hand side of the Zero Two chassis. It may be daisy-chained allowing one FM002A to serve up to 100 Zero Two modules in any combination.
IN042 Four Zone Control Module

IN042 Four Zone Control Module

The IN042 is a four zone input module designed for use with two-wire field devices such as smoke or heat detectors, pull switches and manual callpoints. It is designed to monitor these devices and provide both status indication and fault / alarm outputs for each zone.
MD002 Monitored Driver Output Module

MD002 Monitored Driver Output Module

The MD002 is a monitored driver output module designed for four independent outputs requiring monitoring in their non-active state, such as extinguishing solenoids, beacons, horns, etc. Each driver is independent and has circuitry to monitor short and open circuits in field wiring.
ZN002A Three Zone Control Module

ZN002A Three Zone Control Module

The ZN002A is a Zone Control Module for the Zero Two Series Fire and Gas Detection System. The ZN002A provides zoning and voting functions for three separate and independent zones of gas and / or flame detection.